Vertiv Liebert Powerbank 600 RT 3 X 1 UPS

Vertiv Liebert Powerbank 600 RT 3 X 1 UPS 6kVA / 6kW True Online UPS with Three-Phase Input & Single-Phase Output

Vertiv Liebert Powerbank 600 RT 3 X 1 UPS is a fully digital 6kVA / 6kW True Online double-conversion UPS designed for edge computing, IT racks, network closets, automation systems and other critical loads. It combines an input-side isolation transformer, unity output power factor, rack/tower flexibility and integrated communication capabilities in a compact 13U platform.

True Online double conversion Input isolation transformer Rack & tower convertible
VERTIV POWERBANK 600 RT
3-PHASE INPUT
6kVA 6kW
1-PHASE OUTPUT
ISOLATION TRANSFORMER → RECTIFIER → DC BUS → INVERTER
STATIC & MAINTENANCE BYPASS
UNITY PF 13U RACK / TOWER
Conceptual illustration — Liebert Powerbank 600 RT 3 X 1 double-conversion and 3-phase-input power architecture
6 kVA UPS power rating
6 kW Active power capacity
0.99 Input PF at full load
4 Units Maximum parallel capacity
Liebert Powerbank 600 RT 3 X 1 Overview

Compact 6kVA UPS for Edge & Critical Applications

Vertiv Liebert Powerbank 600 RT 3 X 1 UPS provides 6kVA / 6kW of online power protection using a three-phase input and single-phase output architecture.

True Online double conversion continuously converts incoming AC power through the DC bus before recreating the conditioned AC output used by connected equipment.

The 3 X 1 configuration incorporates its isolation transformer on the input side, providing electrical isolation within the incoming power path.

A rated output power factor of unity allows the full 6kVA rating to deliver up to 6kW of active power.

The input stage accepts a broad voltage window, allowing the UPS to remain on utility power across a wider range of input conditions before battery operation is required.

The rack/tower convertible enclosure allows the same UPS platform to be deployed horizontally in compatible racks or vertically as a tower.

Integrated Ethernet connectivity, Modbus and SNMP capabilities allow the UPS to communicate with compatible network-management, BMS and SCADA environments.

Automatic and manual battery diagnostics, audible and visual alarms, surge protection and configurable battery options complement the critical-power architecture.

Liebert Powerbank 600 RT 3 X 1 Features

Digital UPS Technology for Compact Critical-Power Environments

The Powerbank 600 RT combines online power conversion, electrical isolation, battery diagnostics, network communication and flexible rack/tower deployment.

True Online Double Conversion

Incoming power is continuously converted through the DC stage before the inverter generates the conditioned AC output.

Inbuilt Isolation Transformer

The 3 X 1 configuration includes an input-side isolation transformer within the UPS power path.

Wide Input Voltage Window

The three-phase input accommodates 305–498Vac at full load and a wider range at reduced load.

Power-Factor Optimised Design

Input power factor reaches at least 0.99 at full load, while unity output power factor enables 6kW from the 6kVA UPS.

Battery Diagnostics & Early Warning

Automatic and manual battery testing works with audible and visual alarms to indicate important UPS operating conditions.

Integrated Connectivity

Built-in Ethernet, Modbus and SNMP capabilities enable communication with compatible network, BMS and SCADA environments.

3Ø INPUT
ISO
DC BUS
1Ø OUT
BATTERY ⇄ DC BUS
STATIC
BYPASS
BATTERY
TEST
ETHERNET
MODBUS
TRUE ONLINE DOUBLE-CONVERSION POWER PATH
Three-Phase Input, Single-Phase Output Architecture Three-phase utility power passes through the input isolation transformer and double-conversion power stages before the UPS delivers conditioned single-phase output to connected loads. Conceptual illustration — Liebert Powerbank 600 RT 3 X 1 transformer, DC bus, inverter and bypass architecture
Liebert Powerbank 600 RT 3 X 1 Technology

Fully Digital True Online Power Conversion

Vertiv Liebert Powerbank 600 RT 3 X 1 UPS combines three-phase input power, electrical isolation, online double conversion and single-phase conditioned output in a compact rack/tower platform.

  • 6kVA / 6kW three-phase-input UPS
  • True Online double-conversion topology
  • Inbuilt input-side isolation transformer
  • Unity output power factor
  • Input power factor ≥0.99 at full load
  • 40–70Hz input-frequency range
  • 0ms mains-to-battery transfer
  • Static and maintenance bypass
  • Parallel operation up to four UPS units
  • Rack and tower convertible enclosure
Liebert Powerbank 600 RT 3 X 1 Applications

Compact Online UPS Power for Edge & Critical Equipment

IT Racks & Network Closets Conditioned UPS power for compatible rack equipment, switches, network devices and edge-computing systems.
Data Centres & Server Farms 6kW online power protection for compatible computing and server infrastructure.
Automation & Control Systems Conditioned backup power for compatible automation equipment and compact control environments.
Telecom & Precision Equipment Online UPS power for compatible telecommunications equipment, workstations and analytical or precision instruments.
Liebert Powerbank 600 RT Technology

Vertiv Liebert Powerbank 600 RT 3 X 1 UPS

A 6kVA / 6kW rack/tower platform combining three-phase input, single-phase output and integrated digital power-management features.

Vertiv Liebert Powerbank 600 RT 3 X 1 UPS Liebert Powerbank 600 RT Powerbank 600 RT 3 X 1 6kVA UPS 6kW UPS Three-Phase Input UPS Single-Phase Output UPS True Online UPS Double Conversion UPS Unity Power Factor Isolation Transformer Rack Tower UPS Static Bypass Maintenance Bypass Battery Diagnostics Built-in Ethernet Modbus SNMP Lithium-Ion Compatible SMF VRLA Battery
Liebert Powerbank 600 RT 3 X 1 Technical Information

Vertiv Liebert Powerbank 600 RT 3 X 1 UPS Specifications

Key input, output, efficiency, battery, communication and mechanical characteristics of the 6kVA 3 X 1 configuration.

Manufacturer
Vertiv
Product
Liebert Powerbank 600 RT 3 X 1
Power rating
6kVA / 6kW
Phase configuration
Three-phase input / single-phase output
UPS topology
True Online double conversion
Rated input voltage
415Vac
Input voltage at full load
305–498Vac
Input voltage at 50% load
174–498Vac
Rated input frequency
50Hz / 60Hz
Input frequency range
40–70Hz
Input power factor
≥0.99 at full load
Isolation transformer
Inbuilt at input side
Output voltage
220 / 230 / 240Vac, single phase
Output power factor
Unity
Crest factor
3:1
Output voltage regulation
±1%
Output voltage distortion
<1% linear load; <8% non-linear load
Dynamic response recovery
60ms
Frequency synchronization
Rated frequency ±3Hz; configurable ±0.5Hz to ±5Hz
Parallel capacity
Maximum 4 units in N+1 architecture
Static bypass
Inbuilt
Maintenance bypass
Inbuilt
Online mode efficiency
89%
ECO mode efficiency
Up to 94%
Inverter efficiency
94%
Mains-to-battery transfer
0ms
Inverter-to-bypass transfer
≤0ms when synchronized; ≤20ms asynchronous default
Battery technologies
Sealed lead-acid SMF VRLA or compatible lithium-ion
Battery arrangement
Settable options with 16 batteries by default
Battery charger capacity
5A
Display
Graphical LCD
Network communication
Built-in Ethernet, SNMP and Modbus capabilities
Operating temperature
0°C to 50°C with applicable derating
Relative humidity
5% to 95%, non-condensing
Altitude
Up to 3000m without specified altitude derating
Dimensions
440 × 550 × 550 mm
Rack height
13U
Form factor
Rack / tower convertible
Cooling
Forced-air cooled
Ingress protection
IP20

Values vary by model and configuration; applicable Vertiv product documentation governs the configuration.

Liebert Powerbank 600 RT 3 X 1 FAQs

Frequently Asked Questions About Vertiv Liebert Powerbank 600 RT 3 X 1 UPS

Key information about the 6kVA rating, three-phase input, online topology, rack/tower format and battery options.

What is a Vertiv Liebert Powerbank 600 RT 3 X 1 UPS?

Vertiv Liebert Powerbank 600 RT 3 X 1 UPS is a 6kVA / 6kW True Online double-conversion UPS with three-phase input, single-phase output and an inbuilt input-side isolation transformer.

What is the input and output configuration?

The 3 X 1 model accepts three-phase 415Vac nominal input and delivers selectable 220, 230 or 240Vac single-phase output.

Can Liebert Powerbank 600 RT use lithium-ion batteries?

The Powerbank 600 RT platform can operate with sealed lead-acid SMF VRLA battery configurations and compatible lithium-ion battery arrangements.

What technical parameters vary by model/configuration?

Battery arrangement, autonomy, charging settings, communication options, operating derating and parallel configuration can vary according to the selected system. Values vary by model and configuration; applicable Vertiv product documentation governs the configuration.

Liebert Powerbank 600 RT 3 X 1 Architecture

Double Conversion, Rack/Tower Design & Parallel Power

Explore conceptual views of the online conversion path, rack/tower format and scalable parallel architecture.

Request Vertiv Liebert Powerbank 600 RT 3 X 1 UPS Product Information

Contact Intermax for Vertiv Liebert Powerbank 600 RT 3 X 1 UPS pricing, availability and product information.

Contact Intermax

Get Quote