Microtek 24X7 Hybrid UPS
725VA to 1650VA Hybrid Home Power Backup Series
Microtek 24X7 Hybrid UPS
combines digital and sine-wave technologies within
an intelligent home power-backup platform. The
supplied 24X7 Hybrid Series covers ratings from
725VA with a 12V battery system to 1650VA with a
24V battery system and includes TPZi output,
in-built bypass, CCCV charging, battery-state
monitoring and smart electrical protection.
Hybrid digital technology
In-built bypass
CCCV battery charging
MICROTEK
24X7 HYBRID
HYBRID HOME UPS
DIGITAL
CONTROL
TPZi
OUTPUT
BATTERY → UPS → HOME LOAD
CCCV CHARGING
IN-BUILT BYPASS
BATTERY MONITOR
725VA
HYBRID
1650VA
Conceptual illustration — Microtek 24X7 Hybrid UPS with intelligent control, TPZi output, battery charging and in-built bypass architecture
725–1650 VASupplied 24X7 Hybrid range
725 VASupplied lower rating
1650 VASupplied upper rating
12 VLower-range battery system
24 VUpper-range battery system
Microtek 24X7 Hybrid UPS Overview
Hybrid Digital Power Backup for Home Applications
Microtek 24X7 Hybrid UPS
is designed as a home power-backup series
combining digital control and waveform
technologies within a hybrid UPS architecture.
The supplied series information covers ratings
starting from 725VA with a 12V battery system
and extending to 1650VA with a 24V battery
configuration.
TPZi is specified as the output waveform for the
supplied 24X7 Hybrid Series.
Microcontroller-based intelligent control
supervises the UPS operating functions and
associated battery-management processes.
An in-built bypass function provides a bypass
power path within the UPS architecture when the
inverter section is unavailable.
CCCV battery charging with Auto Trickle Mode
manages the connected external battery bank
through different charging stages.
LED indications communicate operating status and
fault conditions while battery-state monitoring
provides additional information about the
connected battery system.
Standard and narrow mains-input operating ranges,
together with input-voltage range selection,
provide two supplied operating-window references.
Hybrid Power & Bypass Architecture
The intelligent controller manages mains,
battery and inverter operation while the
integrated bypass provides an alternate
power path within the UPS architecture.
Conceptual illustration — Microtek 24X7 Hybrid UPS mains selection, intelligent control, battery charging and bypass architecture
Microtek 24X7 Hybrid UPS Technology
Digital Hybrid Control with Integrated Bypass
Microtek 24X7 Hybrid UPS
combines intelligent microcontroller operation
with battery charging, selectable mains ranges,
TPZi output and an integrated bypass architecture.
725VA to 1650VA supplied range
12V to 24V battery-system endpoints
Digital and waveform hybrid architecture
TPZi output waveform
Microcontroller-based intelligent control
In-built bypass function
CCCV battery charging
Auto Trickle Mode
Battery-state monitoring
Selectable mains-input range
Microtek 24X7 Hybrid UPS Applications
Hybrid Power Backup for Residential Applications
Home Power Backup
Designed for compatible residential
power-backup requirements.
Household Backup Circuits
Supports compatible home electrical circuits
within the selected UPS rating.
Residential Electronics
Backup power for compatible electronic loads
used within home environments.
Home Inverter Systems
External-battery power architecture for
compatible household inverter installations.
Microtek 24X7 Hybrid Technology
Microtek 24X7 Hybrid UPS Features & Range
The supplied series combines different capacity and
battery-system configurations with shared hybrid
control, charging and protection functions.
Microtek 24X7 Hybrid UPS24X7 Hybrid Series725VA1650VA12V Battery System24V Battery SystemTPZi WaveformHybrid TechnologyDigital ControlMicrocontroller ControlIn-Built BypassCCCV TechnologyAuto Trickle ModeLED Status IndicationLED Fault IndicationBattery State MonitoringBattery Voltage SelectionOverload SenseShort Circuit ProtectionInput Range Selection100–300V Standard Range180–260V Narrow Range
Microtek 24X7 Hybrid UPS Technical Information
Microtek 24X7 Hybrid UPS Specifications
The specifications below reflect the supplied 24X7
Hybrid Series product information and are kept
separate from newer Microtek Smart Hybrid models.
Manufacturer
Microtek
Product family
Microtek 24X7 Hybrid UPS
Product type
Home UPS / Inverter
Technology
Hybrid combination of digital and waveform
technologies
Supplied capacity range
725VA to 1650VA
Lower-range battery reference
12V at the supplied 725VA endpoint
Upper-range battery reference
24V at the supplied 1650VA endpoint
Output waveform
TPZi
Control architecture
Microcontroller-based intelligent control design
Bypass
In-built bypass function
Standard input-voltage range
100V–300V
Narrow input-voltage range
180V–260V
Input-range selection
Mains Input Voltage Range Slide Selection Switch
Battery-voltage control
Battery Voltage Selection Switch described in
the supplied series information
Display
LED status and fault indications
Charging technology
CCCV technology with Auto Trickle Mode
Battery monitoring
Battery State Monitoring
Overload protection
Smart Overload Sense
Short-circuit protection
Supported
Battery architecture
External battery system with voltage dependent
on the applicable UPS configuration
Specification note
Detailed technical values vary by legacy
production configuration; current Microtek
documentation governs the supplied configuration.
Microtek 24X7 Hybrid UPS FAQs
Frequently Asked Questions About Microtek 24X7 Hybrid UPS
Key information about capacity, hybrid technology,
bypass functionality and model-dependent
specifications.
?
What is the Microtek 24X7 Hybrid UPS?
Microtek 24X7 Hybrid UPS
is a home power-backup series combining
digital control, TPZi output, intelligent
battery management and an in-built bypass
architecture.
?
What capacity range does the Microtek 24X7 Hybrid UPS cover?
The supplied series information describes
ratings from 725VA with a 12V battery system
to 1650VA with a 24V battery system.
?
Does the Microtek 24X7 Hybrid UPS have an in-built bypass?
Yes. The supplied 24X7 Hybrid Series
information describes an in-built bypass
function that provides an alternate power
path within the UPS architecture.
?
What technical parameters vary by model/configuration?
VA capacity, battery-system voltage and
additional electrical characteristics depend
on the individual 24X7 Hybrid configuration.
Detailed technical values vary by legacy
production configuration; current Microtek
documentation governs the supplied configuration.
Microtek 24X7 Hybrid UPS Architecture
Hybrid Control, Bypass & Battery Architecture
Explore conceptual views of the complete 24X7 Hybrid
UPS, hybrid power path and CCCV battery-management
architecture.