Get Quote

MAHINDRA POWEROL DIESEL GENSETS

Mahindra Powerol diesel gensets

Mahindra Powerol Diesel Gensets – 5kVA to 625kVA CPCB IV+ Backup Power for Commercial and Industrial Applications

Mahindra Powerol diesel gensets provide dependable standby and prime-power options across a broad 5kVA to 625kVA range. Designed for commercial, industrial and infrastructure applications, the range combines diesel-engine technology, regulated electrical output, acoustic enclosure options, safety functions and modern CPCB IV+ emission-control technology.

5kVA to 625kVA range CPCB IV+ technology Manual and automatic control options
MAHINDRA POWEROL DIESEL GENSET
DIESEL ENGINE
ALTERNATOR
CPCB IV+ POWER GENERATION 5kVA – 625kVA
Conceptual illustration — Mahindra Powerol acoustic diesel genset
5–625kVA Diesel generator range
5–625kVA Power range
50Hz India frequency
0.8 PF Typical rated power factor
CPCB IV+ Current emission technology
Mahindra Powerol Diesel Gensets Overview

Diesel Backup Power for Diverse Critical Applications

Mahindra Powerol diesel gensets are designed to provide an independent source of electrical power when the normal utility supply is unavailable or unsuitable for the connected load.

The portfolio spans compact low-kVA generators for smaller commercial loads through higher-capacity three-phase generator sets for industrial, healthcare, infrastructure and commercial facilities.

Mahindra Powerol combines diesel engines with compatible alternators and generator controls to produce regulated AC power. Depending on rating, available configurations include single-phase or three-phase output and different control-panel arrangements.

Automatic Mains Failure configurations can monitor the normal electrical supply and initiate generator operation when predetermined mains conditions are detected. Manual control configurations are also available across applicable models.

Acoustic canopy construction, vibration control and engine design help reduce the noise and vibration associated with diesel power generation. Exact enclosure and acoustic performance varies by model.

Current Mahindra Powerol diesel-generator technology incorporates CPCB IV+ emission-control requirements for applicable Indian models, supporting compliance with the current regulatory framework.

Optional communication and remote-monitoring capabilities are available on applicable configurations for operating status, generator parameters and fault visibility.

Mahindra Powerol Diesel Gensets Features

Engineered for Efficient and Dependable Backup Power

Product features vary by capacity, engine platform, control configuration and application requirement.

Broad 5kVA–625kVA Range

Multiple power ratings allow generator capacity to be selected around commercial, industrial and infrastructure load requirements.

CPCB IV+ Technology

Applicable current-generation models use emission-control technology designed around India’s CPCB IV+ requirements.

Efficient Diesel Engines

Engine platforms are selected to combine required power output with controlled fuel consumption across rated operating conditions.

Automatic Control Options

Applicable configurations support AMF control for automatic generator start and mains-to-generator transfer logic.

Low-Noise Enclosure Design

Acoustic enclosure and vibration-management features help control generator noise and mechanical vibration.

Remote Monitoring Options

Compatible models can support remote operating information and generator-status monitoring.

UTILITY Normal Supply
AMF / ATS Transfer Logic
LOAD Facility Power
DIESEL GENSET Engine + Alternator
ENGINE AC POWER
50Hz Frequency
230/415V Model Dependent
0.8 PF Typical Rating
Automatic Backup Power Architecture In an applicable AMF configuration, the control system detects mains conditions, starts the generator and enables transfer of the selected load to generator power. Conceptual illustration — utility and diesel-generator backup power path
Mahindra Powerol DG Set Operation

From Diesel Engine Power to Regulated AC Output

The diesel engine converts fuel energy into mechanical rotation. The alternator converts this mechanical power into AC electrical power for the connected load.

  • Diesel-engine prime mover
  • Brushless alternator on applicable models
  • 50Hz electrical output
  • 1500 RPM on many industrial ratings
  • Single or three-phase models
  • 230V / 415V options by rating
  • Manual control-panel options
  • AMF control options
  • Electrical protection functions
  • Remote monitoring on compatible configurations
Mahindra Powerol Diesel Gensets Applications

Backup and Prime Power Across Commercial and Industrial Sectors

Hospitals & Healthcare Backup generation for compatible clinical, electrical and facility loads.
Telecommunications Generator power for telecom sites, communication rooms and network infrastructure.
Banking & Finance Backup power for branches, transaction systems and business-critical infrastructure.
Manufacturing Power generation for compatible production, automation and facility loads.
Construction Sites Temporary or standby electrical power for compatible construction-site equipment.
Hotels & Commercial Buildings Backup generation for selected building systems and commercial electrical loads.
Retail & Petrol Pumps Power continuity for transaction equipment, lighting and selected facility systems.
Railway & Infrastructure Generator power for compatible infrastructure, signalling, communications and utility loads.
Ratings and Generator Technology

Mahindra Powerol Diesel Gensets Range

Exact engine, alternator, fuel consumption, dimensions, controls and output specifications vary by selected kVA rating.

Mahindra Powerol Diesel Gensets 5kVA 10kVA 15kVA 20kVA 25kVA 30kVA 40kVA 50kVA 62.5kVA 75kVA 100kVA 125kVA 160kVA 200kVA 250kVA 320kVA 400kVA 500kVA 625kVA CPCB IV+ 50Hz Single Phase Three Phase AMF Control Manual Control Optional Remote Monitoring Acoustic Canopy
Mahindra Powerol Technical Information

Mahindra Powerol Diesel Gensets Specifications

The specifications below describe the product family. Always confirm the selected generator rating because engine, phase, fuel tank, dimensions, weight and control architecture vary substantially across the range.

Manufacturer
Mahindra Powerol
Product type
Diesel engine generator set
Published diesel range
5kVA to 625kVA
Duty
Prime or standby depending on model and rating
Rated frequency
50Hz on Indian product configurations
Output phase
Single phase and/or three phase depending on model
Nominal voltage
Common configurations include 230V single phase and 415V three phase; verify selected rating
Rated power factor
0.8 lagging on many commercial and industrial models
Engine speed
Common industrial configurations operate at 1500 RPM at 50Hz; smaller models may differ
Engine configuration
Model dependent; naturally aspirated, turbocharged and turbocharged/intercooled platforms are used across the range
Number of cylinders
Model dependent
Starting system
Electric starting; 12V or 24V DC depending on model
Fuel
High-speed diesel for applicable diesel models
Fuel-tank capacity
Model and rating dependent
Fuel consumption
Depends on generator rating, engine platform, operating load and environmental conditions
Governing system
Mechanical or electronic depending on generator rating and engine platform
Alternator
Generator-rated alternator selected according to model and output requirement
Alternator insulation
Class H on many Mahindra Powerol industrial models
Alternator enclosure
IP23 on many published industrial configurations
Voltage regulation
Approximately ±1% on many published models; verify selected genset specification
Control-panel options
Manual and automatic mains-failure configurations depending on model
Remote monitoring
Optional GPRS or compatible monitoring capabilities on applicable configurations
Acoustic enclosure
Available according to model and generator configuration
Emission standard
Current applicable Indian models are designed around CPCB IV+ requirements
Exhaust after-treatment
Technology varies by engine rating and CPCB IV+ configuration and can include modern emission-control systems
Dimensions
Model and kVA dependent
Approximate weight
Model and kVA dependent
Selection information
Confirm running load, motor-starting loads, phase, voltage, duty, required autonomy, site conditions, control mode and expected future load growth
Typical applications
Telecom, hospitals, hotels, banking, manufacturing, construction, retail, petrol pumps, infrastructure, offices and commercial facilities
Mahindra Powerol Diesel Gensets FAQs

Frequently Asked Questions About Mahindra Powerol Diesel Gensets

Key information about capacities, applications, automatic operation and generator selection.

What capacities are available in Mahindra Powerol diesel gensets?

Mahindra Powerol currently lists a diesel generator portfolio ranging from 5kVA to 625kVA for different backup and prime-power requirements.

Are Mahindra Powerol diesel gensets CPCB IV+ compliant?

Mahindra Powerol’s current Indian generator technology includes CPCB IV+ compliant configurations. Compliance should be verified against the exact generator model selected.

Can a Mahindra Powerol genset start automatically during a power cut?

Applicable gensets can be paired with an AMF control arrangement that detects mains failure and controls generator starting and power transfer.

How should the correct diesel genset capacity be selected?

Selection should consider total running load, motor and compressor starting current, phase, power factor, operating duty, site conditions and anticipated future load growth.

Mahindra Powerol Generator Architecture

Genset, Control Panel and Power-System Views

Explore the acoustic generator enclosure, generator control architecture and mains-backup power arrangement.

Request Mahindra Powerol Diesel Gensets Product Information

Contact Intermax for Mahindra Powerol diesel gensets pricing, availability, capacity options and product information.

Contact Intermax

Get Quote