Get Quote

Liebert APM 30kW – 300kW

Liebert APM UPS

Liebert APM UPS 30kW to 300kW Vertiv Modular Online UPS with FlexPower Technology

Liebert APM UPS is a compact, modular and scalable online UPS system designed to protect small and medium computer rooms, data centres and business-critical infrastructure. Its FlexPower technology combines distributed intelligence and scalable power within a compact common assembly.

30kW modular increments Up to 96% online efficiency Hot-swappable modules
VERTIV LIEBERT APM
30kW 30kW 30kW 30kW
30kW 30kW 30kW N+1
FLEXPOWER TECHNOLOGY
30kW START
MODULE 1 MODULE 2 MODULE 3
PAY AS YOU GROW
300kW Maximum range capacity
30–300kW Scalable UPS range
30kW Power-module capacity
96% Online efficiency
1.0 PF Unity output factor
Liebert APM UPS Overview

Liebert APM UPS for Scalable Critical Power Protection

Liebert APM UPS is a modular, transformer-free, three-phase online UPS system designed for small and medium computer rooms, data centres and other mission-critical applications.

The system starts from 30kW and scales to 300kW using 30kW power modules. Capacity can be aligned with current requirements and expanded later as the protected load increases.

FlexPower technology combines scalable power with distributed intelligence. Each power module incorporates independent DSP control to regulate operation and share the connected load.

Hot-swappable module construction supports individual power-module replacement without shutting down the complete system, provided sufficient remaining capacity is available.

The Liebert APM UPS provides true online double-conversion protection with operating efficiency up to 96% and ECO-mode efficiency up to 98%.

Unity output power factor means the available kVA capacity is equal to the active kW capacity. Each 30kVA module can therefore provide 30kW of usable active power.

Flexible batteries, front-access maintenance, parallel-system capability and communication through web, Modbus and SNMP help support different runtime, availability and monitoring requirements.

Liebert APM UPS Features

Modular Capacity, High Efficiency and Compact Footprint

The modular architecture combines scalable power, distributed control, flexible battery configurations and front-access maintenance.

FlexPower Scalability

Expand the installed UPS capacity in 30kW increments as the protected critical load grows.

Hot-Swappable Power Modules

Compatible modules can be removed or replaced while the remaining UPS capacity continues supporting the connected load.

Distributed DSP Intelligence

Each module uses independent digital control for operating regulation and accurate load sharing.

High Power Density

Modular construction provides substantial active power within a compact computer-room or data-centre footprint.

Flexible Battery Configuration

Flexible battery-string and cabinet arrangements support different backup runtime and redundancy requirements.

Advanced Communication

Web, Modbus and SNMP communication options support remote monitoring and facility-management integration.

AC INPUT Utility
RECTIFIER AC to DC
DC BUS Battery
INVERTER DC to AC
30kW
DSP MODULE
30kW
DSP MODULE
30kW
DSP MODULE
FLEXPOWER CAPACITY + REDUNDANCY
Distributed Modular Power Architecture Independent 30kW modules share the critical load and allow capacity or internal redundancy to be expanded inside the modular UPS system.
Liebert APM UPS FlexPower

Add UPS Capacity as Your Critical Power Demand Grows

The Liebert APM UPS allows the initial capacity to be configured around current requirements and expanded through compatible 30kW power modules.

  • 30kW modular power units
  • Hot-swappable module architecture
  • Independent DSP module control
  • Automatic load sharing
  • Unity output power factor
  • Vertical capacity expansion
  • Configurable N+1 redundancy
  • Parallel-system capability
  • Dual-bus configuration support
  • Pay-as-you-grow scalability
Liebert APM UPS Applications

Scalable UPS Protection for Critical Business Infrastructure

Computer Rooms Compact power protection for small and medium business-critical computer rooms.
Data Centres Scalable online UPS power for servers, storage and networking infrastructure.
Colocation Facilities Flexible capacity and redundancy for changing customer power requirements.
Banking and Finance Reliable power for transaction systems, processing infrastructure and financial data.
Telecommunications Modular protection for network, switching and communication infrastructure.
Healthcare IT Online power protection for healthcare servers, communications and digital systems.
Manufacturing Reliable power continuity for automation, production and industrial IT systems.
Government Facilities Scalable UPS protection for critical public-sector computing and data infrastructure.
Liebert APM UPS Technology

Liebert APM UPS 30kW to 300kW Configuration

Modular power, flexible batteries and advanced communication support varied capacity, runtime, redundancy and monitoring requirements.

Liebert APM UPS 30kW to 300kW 30kW Power Modules FlexPower Technology Online Double Conversion Transformer-Free Unity Output PF Distributed DSP Hot-Swappable Modules 96% Online Efficiency Up to 98% ECO Mode Input PF Above 0.99 Input THDi Below 3% N+1 Redundancy Parallel Ready Dual Bus Ready Flexible Batteries Full Front Access Multilingual LCD HTTP Modbus SNMP
Liebert APM UPS Technical Information

Liebert APM UPS 30kW to 300kW Specifications

Cabinet dimensions, battery runtime and system weight depend on the selected power rating, module quantity, battery arrangement and distribution configuration.

Manufacturer
Vertiv
Product name
Liebert APM UPS
Product type
Modular three-phase online UPS
Power range
30kW to 300kW
Power-module rating
30kW per module
UPS topology
True online double conversion
Internal architecture
Transformer-free modular design
Scalability
FlexPower technology with 30kW expansion increments
Module control
Independent DSP control in each power module
Module replacement
Hot-swappable power-module architecture
Online efficiency
Up to 96%
ECO-mode efficiency
Up to 98%
Output power factor
1.0 unity power factor
Rated input voltage
380V, 400V or 415V AC
Input phase
Three-phase, four-wire
Input voltage range
305V to 477V; operation from 208V to 304V with load derating
Rated frequency
50Hz or 60Hz
Input frequency range
40Hz to 70Hz
Input power factor
At least 0.99 at full load and above 0.98 at half load
Input-current distortion
Less than 3% THDi under specified conditions
Output voltage
380V, 400V or 415V AC
Output phase
Three-phase, four-wire
Output-voltage stability
±1%
110% inverter overload
Up to 60 minutes
125% inverter overload
Up to 10 minutes
150% inverter overload
Up to one minute
Battery configuration
Flexible internal or external battery configurations
Battery-string options
Configurable 30, 32, 34, 36, 38 or 40 battery blocks, depending on system configuration
Battery management
Intelligent battery-management functionality
Internal redundancy
Configurable modular N+1 redundancy
Parallel operation
Supported for capacity or redundancy expansion
Dual-bus capability
Supported through compatible load-bus synchronisation configurations
Bypass
Static bypass and maintenance-bypass functionality
Local interface
Multilingual large LCD human-machine interface
Communication
Web, HTTP, Modbus and SNMP options
Service access
Full front access
Cable entry
Top and bottom cable-entry options
Operating temperature
0°C to 40°C under specified operating conditions
Applications
Computer rooms, data centres, banking, healthcare, telecommunications, manufacturing and government infrastructure
Liebert APM UPS FAQs

Frequently Asked Questions About Liebert APM UPS

Key information about scalability, efficiency, redundancy and battery configurations.

What is the capacity range of Liebert APM UPS?

The Liebert APM UPS range starts at 30kW and can scale to 300kW using compatible 30kW modular power units.

What is FlexPower technology?

FlexPower technology combines scalable power modules with distributed digital intelligence inside a common modular UPS assembly.

What is the efficiency of Liebert APM UPS?

The system provides online double-conversion efficiency up to 96% and ECO-mode efficiency up to 98%.

Can Liebert APM UPS modules be replaced during operation?

The modular power units are designed for hot-swappable replacement, subject to sufficient remaining capacity and the approved operating procedure.

Liebert APM UPS Architecture

Liebert APM UPS Modular System Views

Explore the modular cabinet, hot-swappable power unit and scalable parallel-system architecture.

Request Liebert APM UPS Pricing

Contact Intermax for Liebert APM UPS pricing, availability, capacity options and product information.

Contact Intermax

Get Quote